INSTALASI LISTRIK MASJID AL-IKHLAS KAMPUNG KARET-BATU BESAR KECAMATAN NONGSA KOTA BATAM
DOI:
https://doi.org/10.37776/pend.v1i1.1221Keywords:
PUIL, ELCB, AKLI, PKMAbstract
The people of Kampung Karet, Nongsa District, most of them still don't understand about electrical installations, the condition of the electrical installation system in people's homes and especially places of worship (mosques) are still many that do not comply with general regulations regarding electrical installations. Apart from that, there are still many connections. -connection of electrical installations carried out by the community itself which does not comply with regulations. Community service by providing counseling and going directly to see the location that is the target of carrying out service activities, namely the Al-Ikhlas mosque. By holding community service (PKM), the residents of Rubber Village will understand how to install electricity properly, correctly and safely. The equipment selected for installation in an electrical installation must meet applicable standards and must be suitable for its environment. Installation of equipment must comply with the provisions in PUIL, and match the equipment manufacturer's instructions. Electrical installations must be regularly inspected and tested for misuse, damage or poor installation, including loose connections. To protect against leakage currents, an ELCB can be installed. In order to achieve an increase in public knowledge and understanding about the importance of electrical hazards, this activity needs to be sustainable.References
Badan Standarisasi Nasional. (2000). Penggunaan dan Pemasangan Perlengkapan Listrik. SNI 04- 0225-2000. Badan Standarisasi Nasional (BSN).
Badan Standarisasi Nasional. (2011). Persyaratan Umum Instalasi Listrik 2011. SNI 0225:2011. Badan Standarisasi Nasional (BSN).
Berahim, H. (2009). Pengantar Teknik Tenaga Listrik. Yogyakarta: Penerbit Andi.
Abrar Tanjung,Zulfahri,Hamzah,(2020) Penggunaan Earth Leakage Circuit Breaker (ELCB) Dan Grounding Sebagai Pengaman Di Kelurahan Limbungan Baru Kecamatan Rumbai Pesisir, Universitas Lancang Kuning 1(1), (7-13).
D. C. Idoniboyeobu, T. K. Bala, and E. Okekem, (2018). “Assessment and Evaluation of Soil Effect on Electrical Earth Resistance : A Case Study of Woji,” Int. J. Eng. Tech. Res., vol. 0869, no. 6, pp. 84–94.
Fathurrozi Winjaya, Arief Darmawan, Mariana Diah, Agustinus (2022), Sosialisasi keamanan dan keselamatan dalam penggunaan listrik di PPI Madiun. 25–30.
F. D. Sukardi, A. Zain, and A. Muliawan, (2019). “Prototipe Pengaman Peralatan Instalasi Listrik dan Tegangan Sentuh Bagi Manusia dengan ELCB ( Earth Leakege Circuit Breaker ),” J. Teknol. Elekterika, vol. 16, no. 2, pp. 56-62.
Indra, Z., & Kamil, I. (2011). Analisis Sistem Instalasi Listrik Rumah Tinggal dan Gedung untukMencegah Bahaya Kebakaran. Analisis Sistem Instalasi Listrik Rumah Tinggal Dan GedungUntuk Mencegah Bahaya Kebakaran, 2(1), 40–44.
Perda Kota Batam No. 2 Tahun 2005 tentang Pemekaran Daerah.
Peraturan Menteri Energi dan Sumber Daya Mineral Nomor: 0045 Tahun 2005
PUIL 2000, Persyaratan Umum Instalasi Listrik 2000, Kemetrian ESDM, Jakarta
S. Sunarto and T. Trisnawiyana, (2021). “Studi perbandingan hasil pengukuran resistansi pembumian menggunakan tiga metode pengukuran yang berbeda,” JITEL (Jurnal Ilm. Telekomun. Elektron. dan List. Tenaga), vol. 1, no. 2, pp. 155–162.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2023 Gunawan Toto Hadiyanto, Djoko; Bambang, Nurhatisyah, Nur
This work is licensed under a Creative Commons Attribution 4.0 International License.